HVAC monitoring and control
AHUs, FCUs, VAV boxes, chillers, pumps and cooling towers under direct digital control — setpoints, schedules, sequencing and demand-based operation from the supervisory interface.
Honeywell BMS on the Niagara Framework — HVAC, lighting and energy under one supervisory layer, with alarm management for the command centre and the approved mechanical responses of the fire cause-and-effect matrix applied on receipt of the alarm.
A building management system earns its place when it does three things well: controls the mechanical plant reliably, reports what matters to the people who operate the facility, and integrates the other systems — fire, security, metering, OT — without a second platform. ESC delivers Honeywell BMS on the Niagara Framework for exactly that, using BACnet and Modbus to bring third-party equipment into one supervisory layer.
ESC holds Honeywell Gold Partner 2026 status under the Catalyst META BMS Program, a separate programme certificate from the fire programme. The BMS scope covers design of the points schedule and architecture, controller and field device supply, panel and field installation, Niagara programming and graphics, witnessed commissioning and long-term support in the Kingdom.
Direct digital control where ESC owns the plant; open-protocol integration where another vendor does.
AHUs, FCUs, VAV boxes, chillers, pumps and cooling towers under direct digital control — setpoints, schedules, sequencing and demand-based operation from the supervisory interface.
Lighting schedules and occupancy-based control, electrical and water sub-metering, consumption dashboards and reporting that give the facility team an evidence base for energy decisions.
Temperature, humidity, CO₂ and air-quality points with trend logging and setpoint correction — for occupant comfort in offices, and for tighter envelopes in data halls and healthcare spaces.
Centralised alarm reception with priorities, escalation and audit-ready history, presented on operator graphics in the command centre alongside fire, security and OT events.
The approved mechanical responses of the fire alarm matrix applied on the BMS side on receipt of the alarm — AHU shutdown, damper positions, pressurisation, lift and door interfaces — with the sequence tested end to end with the fire system.
BACnet and Modbus integration of chillers, generators, UPS, ATS, metering and SCADA or OT equipment, so the supervisory layer shows the whole facility rather than one vendor's plant.
BMS documentation follows the points schedule from design to as-built, so the reviewer can trace every input and output.
Points schedule, architecture and sequences of operation to the consultant specification; controller sizing and network design.
Honeywell supervisory and field controllers, sensors, actuators and software through the authorized channel.
Control panels, field wiring and network cabling to the approved shop drawings, with method statements and ITPs.
Point-to-point checks, loop tuning, sequence verification and witnessed FAT/SAT, including the fire cause-and-effect test with the fire system.
As-built drawings, Niagara graphics and programming backups, O&M manuals and operator training.
Maintenance, remote assistance where the client permits, spares and system updates in the Kingdom.
The BMS programme certificate, valid through 31/12/2026 and separate from the fire programme. Select the record to view the document details.
The scope shown is ESC's systems package. Sensitive references are described in general terms only.